Azad Mashari, Mario Montealegre-Gallegos, Ziyad Knio, Lu Yeh, Jelliffe Jeganathan, Robina Matyal, Kamal R Khabbaz and Feroze Mahmood

Three-dimensional (3D) printing is a rapidly evolving technology with several potential applications in the diagnosis and management of cardiac disease. Recently, 3D printing (i.e. rapid prototyping) derived from 3D transesophageal echocardiography (TEE) has become possible. Due to the multiple steps involved and the specific equipment required for each step, it might be difficult to start implementing echocardiography-derived 3D printing in a clinical setting. In this review, we provide an overview of this process, including its logistics and organization of tools and materials, 3D TEE image acquisition strategies, data export, format conversion, segmentation, and printing. Generation of patient-specific models of cardiac anatomy from echocardiographic data is a feasible, practical application of 3D printing technology.

Open access

Andaleeb A Ahmed, Robina Matyal, Feroze Mahmood, Ruby Feng, Graham B Berry, Scott Gilleland and Kamal R Khabbaz

Objective

Due to its circular shape, the area of the proximal left ventricular tract (PLVOT) adjacent to aortic valve can be derived from a single linear diameter. This is also the location of flow acceleration (FA) during systole, and pulse wave Doppler (PWD) sample volume in the PLVOT can lead to overestimation of velocity (V1) and the aortic valve area (AVA). Therefore, it is recommended to derive V1 from a region of laminar flow in the elliptical shaped distal LVOT (away from the annulus). Besides being inconsistent with the assumptions of continuity equation (CE), spatial difference in the location of flow and area measurement can result in inaccurate AVA calculation. We evaluated the impact of FA in the PLVOT on the accuracy of AVA by continuity equation (CE) in patients with aortic stenosis (AS).

Methods

CE-based AVA calculations were performed in patients with AS once with PWD-derived velocity time integral (VTI) in the distal LVOT (VTILVOT) and then in the PLVOT to obtain a FA velocity profile (FA-VTILVOT) for each patient. A paired sample t-test (P < 0.05) was conducted to compare the impact of FA-VTILVOT and VTILVOT on the calculation of AVA.

Result

There were 46 patients in the study. There was a 30.3% increase in the peak FA-VTILVOT as compared to the peak VTILVOT and AVA obtained by FA-VTILVOT was 29.1% higher than obtained by VTILVOT.

Conclusion

Accuracy of AVA can be significantly impacted by FA in the PLVOT. LVOT area should be measured with 3D imaging in the distal LVOT.